Int J Sports Med 2022; 43(03): 245-253
DOI: 10.1055/a-1537-9757
Training & Testing

Assessment of a Novel, 22-lead Mobile Electrocardiogram in Elite, Adolescent Footballers

1   Bristol Medical School, University of Bristol, Bristol, United Kingdom of Great Britain and Northern Ireland
,
Nuno Duarte
2   Cardiac Physiology Department, Bristol Royal Hospital for Children, Bristol, United Kingdom of Great Britain and Northern Ireland
,
Diane Ryding
3   Physiotherapy Department, Manchester United Ltd, Manchester, United Kingdom of Great Britain and Northern Ireland
,
Dave Perry
4   Football Medicine & Science Department, Manchester United Ltd, Manchester, United Kingdom of Great Britain and Northern Ireland
,
Steve McNally
4   Football Medicine & Science Department, Manchester United Ltd, Manchester, United Kingdom of Great Britain and Northern Ireland
,
A. Graham Stuart
6   Congenital Heart Unit, Bristol Heart Institute, Upper Maudlin Street, National Institute for Health Research Cardiovascular Biomedical Research Centre, Bristol, United Kingdom of Great Britain and Northern Ireland
,
Craig Anthony Williams
5   Children’s Health & Exercise Research Centre, University of Exeter, Exeter, United Kingdom of Great Britain and Northern Ireland
,
Guido Pieles
6   Congenital Heart Unit, Bristol Heart Institute, Upper Maudlin Street, National Institute for Health Research Cardiovascular Biomedical Research Centre, Bristol, United Kingdom of Great Britain and Northern Ireland
7   Institute of Sport Exercise and Health (ISEH), University College London, London, United Kingdom of Great Britain and Northern Ireland
› Author Affiliations
Preview

Abstract

The 12-lead electrocardiogram is a key component of cardiac screening in elite adolescent footballers. Current technology hampers mobile electrocardiogram monitoring that could reduce the time-to-diagnosis in symptomatic athletes. Recently, a 22-lead mobile electrocardiogram monitor, CardioSecur (Personal MedSystems GmbH), has been approved for use in adults. In this study, the differences in parameter accuracy between CardioSecur’s 22-lead electrocardiogram and the gold standard 12-lead electrocardiogram were assessed in elite adolescent footballers (n=31) using Bland-Altman and paired t-tests/Wilcoxon analysis. Agreement between the two devices was clinically acceptable for heart rate (bias=− 0.633 bpm), PR Interval (bias=− 1.73 ms), Bazzett’s corrected QTc interval (bias=2.03 ms), T-wave axis (bias=6.55°), P-wave duration (bias=− 0.941 ms), Q-wave amplitude (bias=0.0195 mV), Q-wave duration (bias=1.98 ms), rhythm (bias=0.0333), ST-segment (bias=− 0.0629), J-point analysis (bias=− 0.01) and extended T wave and QRS duration analysis. Unsatisfactory agreement was observed in QRS axis (bias=− 19.4°), P-wave axis (bias=− 0.670°), QRS amplitude (bias=− 0.660 mV), P-wave amplitude (bias=0.0400 mV) and T-wave amplitude (bias=− 0.0675 mV). CardioSecur’s 22-lead electrocardiogram agrees with the gold standard in rhythm, durations, T-wave determination in all leads assessed, permitting its use in adolescent footballers for immediate pitch- or track-side analysis.

Supplementary Material



Publication History

Received: 29 October 2020

Accepted: 14 June 2021

Article published online:
13 August 2021

© 2021. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany