Endoscopy 2022; 54(05): E232-E233
DOI: 10.1055/a-1494-3055
E-Videos

Intraperitoneal endoscopic salvage using an enteral stent for a misdeployed lumen-apposing metal stent during endoscopic ultrasound-guided gastroenterostomy

Sergio Bazaga
1   Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Spain
,
1   Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Spain
,
Berta Laquente
2   Medical Oncology Department, Institut Català d’Oncologia DiR, Bellvitge Biomedical Research Institute (IDIBELL), L’Hospitalet, Barcelona, Spain
,
1   Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Spain
3   Faculty of Health Sciences, Universitat Oberta de Catalunya, Barcelona, Spain
› Author Affiliations

A 57-year-old man with duodenal carcinoma and a biliary self-expandable metal stent (SEMS) presented with gastric outlet obstruction and an endoscopic ultrasound (EUS)-guided gastroenterostomy was proposed.

After the bowel had been dilated up to 15 mm to allow the gastroscope to be passed across the duodenum, loops of the small bowel were distended with 1 L of saline mixed with methylene blue, using the water-jet channel. A small-bowel loop was then accessed using the freehand technique with the delivery system of an electrocautery-enhanced lumen-apposing metal stent (LAMS; Hot AXIOS; 20 × 10 mm). During advancement of the preloaded guidewire, the bowel loop became tented away and the EUS window was lost, so the distal flange was deployed with concerns of possible misplacement. After deployment of the proximal flange, no flow of blue fluid was noted.

The peritoneal cavity was identified endoscopically through the LAMS and the echoendoscope was exchanged for a therapeutic gastroscope. The guidewire tip, located in the duodenum, was stretched to the outside with the purpose of stabilizing the bowel. Balloon expansion of the LAMS up to 15 mm allowed the gastroscope to be passed into the peritoneal cavity using the LAMS as a trocar. Peritonoscopy was performed under fluoroscopy guidance and the entry point of the guidewire into the bowel was identified ([Fig. 1]). Dilation of the enteral wall up to 8 mm facilitated the advancement of a fully covered SEMS (Niti-S EnteralColonic; 20 × 80 mm; Taewoong Medical) through the LAMS. These technical aspects prevented the risk of tenting away of the bowel loop and loss of the guidewire. Enterography confirmed that the enteral stent was well positioned though the misplaced LAMS, allowing a correct deployment of the rescue stent under fluoroscopy and endoscopy guidance ([Fig. 2]). Lastly, the distal end within the duodenum was checked, and an antimigratory clip was fixed ([Fig. 3]; [Video 1]).

Zoom Image
Fig. 1 Images showing: a, b dilation of a misplaced lumen-apposing metal stent (LAMS) to allow the scope to be passed into the peritoneum; c peritonoscopy being performed through LAMS with the intention of identifying the point of entry of the guidewire inside the bowel.
Zoom Image
Fig. 2 Views of the enteral fully covered self-expandable metal stent deployed within the misplaced lumen-apposing stent to create a bridge between the small bowel and the stomach on: a fluoroscopy; b endoscopy.
Zoom Image
Fig. 3 Fluoroscopic image showing the distal end of the enteral stent being checked from the duodenum.

Video 1 Intraperitoneal endoscopic salvage using an enteral stent for a lumen-apposing metal stent that was misdeployed during the creation of an endoscopic ultrasound-guided gastroenterostomy.


Quality:

Several rescue options have been previously presented for gastroenterostomy [1] [2] [3] [4] [5]. If the wire access to the target loop is not preserved, LAMS misdeployment can require natural orifice transluminal endoscopic surgery (NOTES) or conventional surgery. If the guidewire is secure, a second enteral SEMS can be deployed safely under peritonoscopy and fluoroscopy guidance.

Endoscopy_UCTN_Code_CPL_1AL_2AG

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available.

This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos



Publication History

Article published online:
08 June 2021

© 2021. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Tyberg A, Zerbo S, Barthet M. et al. A novel technique for salvaging a dislodged lumen-apposing metal stent during creation of an endoscopic gastrojejunostomy. Gastrointest Endosc 2016; 83: 254
  • 2 Sanchez-Ocana R, Penas-Herrero I, Gil-Simon P. et al. Natural orifice transluminal endoscopic surgery salvage of direct EUS-guided gastrojejunostomy. VideoGIE 2017; 2: 346-348
  • 3 Ligresti D, Amata M, Barresi L. et al. The lumen-apposing metal stent (LAMS)-in-LAMS technique as an intraprocedural rescue treatment during endoscopic ultrasound-guided gastroenterostomy. Endoscopy 2019; 51: 331-332
  • 4 James TW, Grimm IS, Baron TH. Intraperitoneal echoendoscopy for rescue of a gastrojejunal anastomosis. VideoGIE 2019; 4: 528-529
  • 5 Abdelqader A, Nasr J. Natural orifice transluminal endoscopic salvage of dislodged endoscopic ultrasound-guided jejunogastrostomy stent after endoscopic retrograde in Roux-en-Y anatomy. Am J Gastroenterol 2019; 114: 1024