Int J Sports Med 2021; 42(09): 812-817
DOI: 10.1055/a-1342-7744
Training & Testing

Heart Rate-based Lactate Minimum Test in Running and Cycling

Claudio Perret
1   Institute of Sports Medicine, Swiss Paraplegic Centre, Nottwil, Switzerland
,
Kathrin Hartmann
2   Institute of Human Movement Sciences and Sport, ETH Zürich, Zurich, Switzerland
› Author Affiliations

Abstract

The heart rate-based lactate minimum test is a highly reproducible exercise test. However, the relation between lactate minimum determined by this test and maximal lactate steady state in running and cycling is still unclear. Twelve endurance-trained men performed this test in running and cycling. Exercise intensity at maximal lactate steady state was determined by performing several constant heart rate endurance tests for both exercise modes. Heart rate, power output, lactate concentration, oxygen uptake and rating of perceived exertion at lactate minimum, maximal lactate steady state and maximal performance were analysed. All parameters were significantly higher at maximal lactate steady state compared to lactate minimum for running and cycling. Significant correlations (p<0.05) between maximal lactate steady state and lactate minimum data were found. Peak heart rate and peak oxygen uptake were significantly higher for running versus cycling. Nevertheless, the exercise mode had no influence on relative (in percentage of maximal values) heart rate at lactate minimum (p=0.099) in contrast to relative power output (p=0.002). In conclusion, all measured parameters at lactate minimum were significantly lower but highly correlated with values at maximal lactate steady state in running and cycling, which allows to roughly estimate exercise intensity at maximal lactate steady state with one single exercise test.



Publication History

Received: 07 August 2020

Accepted: 14 December 2020

Article published online:
27 January 2021

© 2021. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Bacon L, Kern M. Evaluating a test protocol for predicting maximum lactate steady state. J Sports Med Phys Fitness 1999; 39: 300-308
  • 2 Beneke R. Methodological aspects of maximal lactate steady state-implications for performance testing. Eur J Appl Physiol 2003; 89: 95-99
  • 3 Beneke R, Hütler M, Leithäuser RM. Maximal lactate-steady-state independent of performance. Med Sci Sports Exerc 2000; 32: 1135-1139
  • 4 Billat VL, Sirvent P, Py G. et al. The concept of maximal lactate steady state: a bridge between biochemistry, physiology and sportscience. Sports Med 2003; 33: 407-426
  • 5 Jones MA, Doust JH, Jonathan H. The validity of the lactate minimum test for determination of the maximal lactate steady state. Med Sci Sports Exerc 1998; 30: 1304-1313
  • 6 Messias LHD, Gobatto CA, Beck WR. et al. The lactate minimum test: Concept, methodological aspects and insights for future investigations in human and animal models. Front Physiol 2017; 8: 389
  • 7 Johnson MA, Sharpe GR, Brown PI. Investigations of the lactate minimum test. Int J Sports Med 2009; 30: 448-454
  • 8 Knoepfli-Lenzin C, Boutellier U. Lactate minimum is valid to estimate maximal lactate steady state in moderately and highly trained subjects. J Strength Cond Res 2011; 25: 1355-1359
  • 9 Perret C, Vrana A. Validation and implementation of the lactate minimum test in rowing. J Sports Sci 2014; 2: 81-89
  • 10 Stangier C, Abel T, Zeller S. et al. Comparison of different blood lactate threshold concepts for constant load performance prediction in spinal cord injured handcyclists. Front Physiol 2019; 10: 1054
  • 11 Carter H, Jones AM, Barstow TJ. et al. Oxygen uptake kinetics in treadmill running and cycle ergometry: A comparison. J Appl Physiol (1985) 2000; 89: 899-907
  • 12 Heck H, Rosskopf P, Hirsch A. et al Einfluss des vorbelastungslaktats, der pausendauer und des belastungsanstiegs auf die laktat- senke. Dtsche Zschr Sportmed 1991; 42: 248-262
  • 13 Jones MA, Sharpe GR, Brown PI. Investigations of the lactate minimum test. Int J Sports Med 2009; 30: 448-454
  • 14 MacIntosh BR, Esau S, Svedahl K. The lactate minimum test for cycling: Estimation of the maximal lactate steady state. Can J Appl Physiol 2002; 27: 232-249
  • 15 Tegtbur U, Busse MW, Braumann KM. Estimation of an individual equilibrium between lactate production and catabolism during exercise. Med Sci Sports Exerc 1993; 25: 620-627
  • 16 Strupler M, Müller G, Perret C. Heart rate based lactate minimum test – a reproducible method. Br J Sports Med 2009; 43: 432-436
  • 17 Perret C, Labruyère R, Müller G. et al. Correlation of heart rate at lactate minimum and maximal lactate steady state in wheelchair racing athletes. Spinal Cord 2012; 50: 33-36
  • 18 Palmer AS, Potteiger JA, Nau KL. et al. A 1-day maximal lactate steady-state assessment protocol for trained runners. Med Sci Sports Exerc 1999; 31: 1336-1341
  • 19 Hoogeveen AR, Hoogsteen J, Schep G. The maximal lactate steady state in elite endurance athletes. Jpn J Physiol 1997; 47: 481-485
  • 20 Harriss DJ, Macsween A, Atkinson G. Ethical standards in sport and exercise science research: 2020 update. Int J Sports Med 2019; 40: 813-817
  • 21 Jones AM, Doust JH. A 1% treadmill grade most accurately reflects the energetic cost of outdoor running. J Sports Sci 1996; 14: 321-327
  • 22 Conconi F, Grazzi Z, Casoni I. et al. The Conconi test: Methodology after 12 years of application. Int J Sports Med 1996; 17: 509-519
  • 23 Borg GA. Psychophysical bases of perceived exertion. Med Sci Sports Exerc 1982; 14: 377-381
  • 24 Roecker K, Striegel H, Dickhuth HH. Heart-rate recommendations: transfer between running and cycling exercise?. Int J Sports Med 2003; 24: 173-178
  • 25 Fontana P, Boutellier U, Knoepfli-Lenzin C. Time to exhaustion at maximal lactate steady state is similar for cycling and running in moderately trained subjects. Eur J Appl Physiol 2009; 107: 187-192
  • 26 Beneke R, von Duvillard SP. Determination of maximal lactate steady state response in selected sport events. Med Sci Sports Exerc 1996; 28: 241-246
  • 27 Millet GP, Vleck VE, Bentley C. Physiological differences between cycling and running: Lessons from triathletes. Sports Med 2009; 39: 179-206
  • 28 Beneke R, Hütler M, von Duvillard SP. et al. Effect of test interruptions on blood lactate during constant workload testing. Med Sci Sports Exerc 35 2003; 1626-1630
  • 29 Carter H, Jones AM, Doust JH. Effect of incremental test protocol on the lactate minimum speed. Med Sci Sports Exerc 1999; 31: 837-845
  • 30 Labruyère R, Perret C. Lactate minimum is influenced by lactic acidosis. Int J Sports Med 2012; 33: 898-902
  • 31 Wahl P, Zwingmann L, Manunzio C. et al. Higher accuracy of the lactate minimum test compared to established threshold concepts to determine maximal lactate steady state in running. Int J Sports Med 2018; 39: 541-548