Z Orthop Unfall 2020; 158(04): 397-405
DOI: 10.1055/a-0969-8675
Review/Übersicht

Infrarotthermografische Untersuchungen nach endoprothetischem Gelenkersatz – ein systematisches Review

Artikel in mehreren Sprachen: English | deutsch
Sebastian Scheidt
1   Department of Orthopaedics and Trauma Surgery University Hospital Bonn, Germany
,
Julian Rüwald
1   Department of Orthopaedics and Trauma Surgery University Hospital Bonn, Germany
,
Frank Alexander Schildberg
1   Department of Orthopaedics and Trauma Surgery University Hospital Bonn, Germany
,
Anne Katrin Mahlein
2   Institute for Sugar Beet Research, University of Goettingen, Germany
,
Axel Seuser
3   Private Practice for Prevention, Rehabilitation and Orthopaedics, Bonn, Germany
,
Dieter Christian Wirtz
1   Department of Orthopaedics and Trauma Surgery University Hospital Bonn, Germany
,
Cornelius Jacobs
1   Department of Orthopaedics and Trauma Surgery University Hospital Bonn, Germany
› Institutsangaben

Zusammenfassung

Hintergrund Veränderungen der Körper- und Hauttemperatur sind Symptom vieler pathologischer Veränderungen des Körpers. Obwohl der künstliche Gelenkersatz von Hüft- und Kniegelenk in den letzten Dekaden große Erfolge feiern konnte, ist die periprothetische Infektion ein zunehmendes Problem und Revisionsgrund Nummer 1. Während viele Arbeiten laborchemische Veränderungen untersuchten, ist die Temperaturdiagnostik bisher nicht in die Routine eingegangen. Diese Arbeit beschäftigt sich mit der Frage, ob in der Literatur für die infratrothermografische Untersuchung von Knie- und Hüftgelenkendoprothetik Referenzbereiche existieren, sich Richtwerte für die Methodik ableiten lassen und ob diese Technik einen peri- und postoperativen Nutzen zeigt.

Material und Methoden Mittels einer systematischen Onlinerecherche und basierend auf den Cochrane-, PICOT- und PRISMA-Richtlinien, erfasst dieses systematische Review 254 Publikationen, von denen 5 mit 251 Patienten in die Auswertung eingegangen sind. Erfasst wurden alle Publikationen der Thematik einer thermografischen Untersuchung bei endoprothetischen Primäroperationen an Hüfte und Knie.

Ergebnisse und Schlussfolgerung Die Infrarotthermografie zeigt sich als nützliches Verfahren in der perioperativen Begleitung von Patienten nach endoprothetischem Ersatz von Knie- und Hüftgelenk. Die Technik ist mobil, einfach in der Anwendung und nicht invasiv. Bereits aus den wenigen zur Verfügung stehenden Arbeiten lassen sich Werte ableiten, welche für die eigenständige thermografische Nachsorge einer endoprothetisch tätigen Klinik oder Praxis eine Orientierung bieten.



Publikationsverlauf

Artikel online veröffentlicht:
16. September 2019

© 2020. Thieme. All rights reserved.

Georg Thieme Verlag KG
Stuttgart · New York

 
  • References/Literatur

  • 1 Walter EJ, Hanna-Jumma S, Carraretto M. et al. The pathophysiological basis and consequences of fever. Crit Care 2016; 20: 200
  • 2 OʼGrady NP, Barie PS, Bartlett JG. et al. Guidelines for evaluation of new fever in critically ill adult patients: 2008 update from the American College of Critical Care Medicine and the Infectious Diseases Society of America. Crit Care Med 2008; 36: 1330-1349
  • 3 Sollai S, Dani C, Berti E. et al. Performance of a non-contact infrared thermometer in healthy newborns. BMJ Open 2016; 6: e008695
  • 4 Knight SR, Aujla R, Biswas SP. Total hip arthroplasty – over 100 years of operative history. Orthop Rev (Pavia) 2011; 3: e16
  • 5 Bozic KJ, Kurtz SM, Lau E. et al. The epidemiology of revision total knee arthroplasty in the United States. Clin Orthop Relat Res 2010; 468: 45-51
  • 6 Haenle M, Skripitz C, Mittelmeier W. et al. Economic impact of infected total knee arthroplasty. ScientificWorldJournal 2012; 2012: 196515
  • 7 Hernández-Vaquero D, Fernández-Fairen M, Torres A. et al. Treatment of periprosthetic infections: an economic analysis. ScientificWorldJournal 2013; 2013: 821650
  • 8 Parvizi J, Tan TL, Goswami K. et al. The 2018 definition of periprosthetic hip and knee infection: an evidence-based and validated criteria. J Arthroplasty 2018; 33: 1309-1314.e2
  • 9 Di Carlo A. Thermography and the possibilities for its applications in clinical and experimental dermatology. Clin Dermatol 1995; 13: 329-336
  • 10 Ring EFJ. The historical development of thermal imaging in medicine. Rheumatology (Oxford) 2004; 43: 800-802
  • 11 Nogueira FE, Medeiros Fd. Barroso LV. et al. Infrared digital telethermography: a new method for early detection of varicocele. Fertil Steril 2009; 92: 361-362
  • 12 Wild W, Schütte SR, Pau HW. et al. Infrared thermography as a non invasive application for medical diagnostic. Proceedings XVII IMEKO World Congress, Dubrovnik, Croatia; 2003: 1744-1748
  • 13 Robicsek F, Masters T, Daugherty H. et al. The value of thermography in the early diagnosis of postoperative sternal wound infections. Thorac Cardiovasc Surg 1984; 32: 260-265
  • 14 Bird HA, Ring EF. Thermography and radiology in the localization of infection. Rheumatol Rehabil 1978; 17: 103-106
  • 15 Seuser A, Kurnik K, Mahlein AK. Infrared thermography as a non-invasive tool to explore differences in the musculoskeletal system of children with hemophilia compared to an age-matched healthy group. Sensors (Basel) 2018; 18: 518 doi:10.3390/s18020518
  • 16 Romanò CL, Romanò D, Bonora C. et al. Combined Diagnostic Tool for joint prosthesis infections. Infez Med 2009; 17: 141-150
  • 17 Widmer AF. New developments in diagnosis and treatment of infection in orthopedic implants. Clin Infect Dis 2001; 33 (Suppl. 02) S94-S106
  • 18 Shih LY, Wu JJ, Yang DJ. Erythrocyte sedimentation rate and C-reactive protein values in patients with total hip arthroplasty. Clin Orthop Relat Res 1987; (225) 238-246
  • 19 Aalto K, Osterman K, Peltola H. et al. Changes in erythrocyte sedimentation rate and C-reactive protein after total hip arthroplasty. Clin Orthop Relat Res 1984; (184) 118-120
  • 20 Berbari E, Mabry T, Tsaras G. et al. Inflammatory blood laboratory levels as markers of prosthetic joint infection: a systematic review and meta-analysis. J Bone Joint Surg Am 2010; 92: 2102-2109
  • 21 Wirtz DC, Heller KD, Miltner O. et al. Interleukin-6: a potential inflammatory marker after total joint replacement. Int Orthop 2000; 24: 194-196
  • 22 Kim SG, Kim JG, Jang KM. et al. Diagnostic value of synovial white blood cell count and serum C-reactive protein for acute periprosthetic joint infection after knee arthroplasty. J Arthroplasty 2017; 32: 3724-3728
  • 23 Karstetter KW, Sherman RA. Use of thermography for initial detection of early reflex sympathetic dystrophy. J Am Podiatr Med Assoc 1991; 81: 198-205
  • 24 Ammer K. The Glamorgan Protocol for recording and evaluation of thermal images of the human body. Thermology International 2008; 18: 125-129
  • 25 Ring EFJ. The historical development of thermometry and thermal imaging in medicine. J Med Eng Technol 2009; 30: 192-198
  • 26 Sweeney SE, Firestein GS. Rheumatoid arthritis: regulation of synovial inflammation. Int J Biochem Cell Biol 2004; 36: 372-378
  • 27 Ring EF, Collins AJ, Bacon PA. et al. Quantitation of thermography in arthritis using multi-isothermal analysis. II. Effect of nonsteroidal anti-inflammatory therapy on the thermographic index. Ann Rheum Dis 1974; 33: 353-356
  • 28 Krieger H. Grundlagen der Strahlungsphysik und des Strahlenschutzes. Wiesbaden: Springer; 2012
  • 29 Hamilton DF, Howie CR, Burnett R. et al. Dealing with the predicted increase in demand for revision total knee arthroplasty: challenges, risks and opportunities. Bone Joint J 2015; 97-B: 723-728
  • 30 Patel A, Pavlou G, Mújica-Mota RE. et al. The epidemiology of revision total knee and hip arthroplasty in England and Wales: a comparative analysis with projections for the United States. A study using the National Joint Registry dataset. Bone Joint J 2015; 97-B: 1076-1081
  • 31 Altman DG, Burton MJ. The Cochrane Collaboration. Langenbecks Arch Surg 1999; 384: 432-436
  • 32 da Costa Santos CM, de Mattos Pimenta CA, Nobre MRC. The PICO strategy for the research question construction and evidence search. Rev Lat Am Enfermagem 2007; 15: 508-511
  • 33 Moher D, Liberati A, Tetzlaff J. et al. Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. Int J Surg 2010; 8: 336-341
  • 34 National Center for Biotechnology Information PubMed. On the Internet: https://www.ncbi.nlm.nih.gov
  • 35 Lambiris E, Stoboy H. Thermographie bei Osteosynthesen und Totalendoprothesen des Kniegelenkes mit und ohne Infektion. Z Orthop Unfall 1981; 119: 521-524
  • 36 Mumingjiang Y, Zhou X, He R. Value of knee skin temperature measured by infrared thermography and soluble intercellular adhesion molecule-1 in the diagnosis of peri-prosthetic knee infection in Chinese individuals following total knee arthroplasty. Chin Med J (Engl) 2014; 127: 3105-3109
  • 37 Romanò CL, Logoluso N, DellʼOro F. et al. Telethermographic findings after uncomplicated and septic total knee replacement. Knee 2012; 19: 193-197
  • 38 Windisch C, Brodt S, Roehner E. et al. Regional differences in temperature course after knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2015; 24: 2686-2691
  • 39 Romanò CL, Romanò D, DellʼOro F. et al. Healing of surgical site after total hip and knee replacements show similar telethermographic patterns. J Orthop Traumatol 2011; 12: 81-86
  • 40 Windisch C, Brodt S, Röhner E. et al. Effects of Kinesio taping compared to arterio-venous Impulse System on limb swelling and skin temperature after total knee arthroplasty. Int Orthop 2017; 41: 855
  • 41 Hischebeth GTR, Gravius S, Buhr JK. et al. Novel diagnostics in revision arthroplasty: implant sonication and multiplex polymerase chain reaction. J Vis Exp 2017; (130) DOI: 10.3791/55147.