Endoscopy 2019; 51(06): E153-E155
DOI: 10.1055/a-0861-9821
E-Videos
© Georg Thieme Verlag KG Stuttgart · New York

Endoscopic ultrasound-guided gastroenterostomy using a metal stent for the treatment of afferent loop syndrome

Yasunari Sakamoto
1   Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
,
Susumu Hijioka
1   Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
,
Yuta Maruki
1   Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
,
Akihiro Ohba
1   Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
,
Yoshikuni Nagashio
1   Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
,
Takuji Okusaka
1   Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
,
Yutaka Saito
2   Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan
› Author Affiliations
Further Information

Publication History

Publication Date:
01 April 2019 (online)

A 79-year-old man with a history of pylorus-preserving pancreaticoduodenectomy for pancreatic head cancer and Child’s reconstruction underwent total pancreatectomy for remnant pancreatic recurrence 2 years later. Four months after total pancreatectomy, he developed cholangitis. Computed tomography (CT) ([Fig. 1]) showed afferent loop syndrome arising from disseminated peritoneal nodule formation. We attempted to place an intestinal stent at the afferent loop stenosis site to resolve the obstructive jaundice and cholangitis.

Zoom Image
Fig. 1 Computed tomography scan showing intestinal and bile duct dilation. At the onset of afferent loop syndrome, disseminated nodules (arrow) were observed.

Although the endoscope (CF-H260AI; Olympus Medical Systems, Tokyo, Japan) reached the stenotic region, advancing the guidewire was difficult and placing the stent was impossible because it was difficult to visualize the stenosis squarely ([Fig. 2]). Thus, the procedure was converted to endoscopic ultrasound (EUS)-guided fistulization from the remnant stomach to the afferent loop ([Video 1]).

Zoom Image
Fig. 2 The intestinal bend and severe stenosis obstructed the guidewire. a Endoscopic image of the intestinal bend. b, c Fluoroscopic images showing severe stenosis.

Video 1 It was difficult to place the stent for stenosis in the afferent loop. We could place the endoscopic ultrasound-guided gastroenterostomy using a metal stent.


Quality:

The afferent loop extending from the remnant stomach was confirmed by EUS, followed by puncture with a 19-gauge needle (EZ Shot 3 Plus; Olympus Medical Systems, Tokyo, Japan) ([Fig. 3 a]). After using contrast imaging to confirm that the needle had penetrated the intestinal tract, a 0.025-inch guidewire (VisiGlide 2; Olympus Medical Systems) was advanced into the dilated intestinal tract ([Fig. 3 b]). Blunt dilation using an ES Dilator (Zeon Medical, Tokyo, Japan) was attempted, but it was difficult; thus, the fistula was dilated using a diathermic dilator (Cysto-Gastro-Set; Endo-Flex GmbH, Voerde, Germany), followed by placement of a fully covered metal stent (X-Suit NIR 10 mm 8 cm; Olympus Medical Systems) ([Fig. 4]). No complications were observed, and the patient’s liver dysfunction and cholangitis promptly improved ([Fig. 5]).

Zoom Image
Fig. 3 Endoscopic ultrasound (EUS)-guided transgastric afferent loop drainage. a Puncture of the dilated intestinal tract under EUS guidance using a 19-gauge needle. b The guidewire was placed in the afferent loop.
Zoom Image
Fig. 4 An X-Suit NIR fully covered metal stent (Olympus Medical Systems, Tokyo, Japan) was placed between the remnant stomach and afferent loop. a Endoscopic ultrasound image taken during deployment of the stent into the afferent loop. b Fluoroscopic image showing the stent (arrow, distal end of the stent; arrowhead, proximal end of the stent). c Endoscopic image taken inside the remnant stomach immediately after stent placement.
Zoom Image
Fig. 5 Computed tomography (CT) image after afferent loop drainage. a Coronal CT showing full view of the metal stent with notch (arrow). b Pneumobilia (arrow) appeared. c The dilation of the afferent loop improved (arrow).

Although previous reports have described the use of plastic stents [1] [2] [3] and lumen-apposing metal stents [3] [4] [5], this is the first report on the use of a tubular type metal stent. This method is effective in treating afferent loop syndrome if placement of an endoscopic intestinal stent is difficult.

Endoscopy_UCTN_Code_TTT_1AP_2AD

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online.
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos

 
  • References

  • 1 Matsumoto K, Kato H, Tomoda T. et al. A case of acute afferent loop syndrome treated by transgastric drainage with EUS. Gastrointest Endosc 2013; 77: 132-133
  • 2 Bamba S, Shiomi H, Fujiyama Y. Afferent loop syndrome successfully treated by endoscopic ultrasound-guided transgastric drainage. Dig Endosc 2013; 25: 632-623
  • 3 Yamamoto K, Tsuchiya T, Tanaka R. et al. Afferent loop syndrome treated by endoscopic ultrasound-guided gastrojejunostomy, using a lumen-apposing metal stent with an electrocautery-enhanced delivery system. Endoscopy 2017; 49: E270-E272
  • 4 Ikeuchi N, Itoi T, Tsuchiya T. et al. One-step EUS-guided gastrojejunostomy with use of a lumen-apposing metal stent for afferent loop syndrome treatment. Gastrointest Endosc 2015; 82: 166
  • 5 Brewer Gutierrez OI, Irani SS, Ngamruengphong S. et al. Endoscopic ultrasound-guided entero-enterostomy for the treatment of afferent loop syndrome: a multicenter experience. Endoscopy 2018; 50: 891-895