Open Access
CC BY-NC-ND 4.0 · Endosc Int Open 2018; 06(10): E1164-E1170
DOI: 10.1055/a-0627-7078
Original article
Owner and Copyright © Georg Thieme Verlag KG 2018

Evaluation of a 12-mm diameter covered self-expandable end bare metal stent for malignant biliary obstruction

Authors

  • Kazunori Nakaoka

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Senju Hashimoto

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Naoto Kawabe

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Takuji Nakano

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Toshiki Kan

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Masashi Ohki

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Yuka Ochi

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Tomoki Takamura

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Takamitsu Kurashita

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Sayuri Nomura

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Keishi Koyama

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Aiko Fukui

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
  • Kentaro Yoshioka

    Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University School of Medicine, Aichi, Japan
Weitere Informationen

Publikationsverlauf

submitted 04. Dezember 2017

accepted after revision 27. April 2018

Publikationsdatum:
08. Oktober 2018 (online)

Preview

Abstract

Background and study aims Biliary metallic stents are used to drain unresectable malignant distal biliary obstructions. This study aimed to evaluate the efficacy of a novel 12-mm-diameter covered, self-expandable end bare metal stent (12-mm CSEEMS).

Patients and methods We evaluated 99 patients with unresectable malignant distal biliary obstructions treated with covered biliary metallic stents. Of the 99 patients, 33 underwent 12-mm CSEEMS placement between June 2015 and April 2017 (12-mm-CSEEMS group) and 66 underwent 10-mm fully-covered self-expandable metal stent (FCSEMS) placement between January 2010 and July 2015 (10-mm-FCSEMS group). The overall survival (OS), the recurrent biliary obstruction (RBO), cause of RBO, time to RBO (TRBO) and adverse events in 12-mm-CSEEMS group and 10-mm-FCSEMS group were evaluated retrospectively.

Results The OS tended to be longer in the 12-mm-CSEEMS group (log rank, P = 0.081) and TRBO was significantly longer in the 12-mm-CSEEMS group (log rank, P = 0.001) than in the 10-mm-FCSEMS group. Both univariate (HR, 0.449; 95 % CI, 0.27967 – 0.72215; P = 0.001) and multivariate (HR, 0.458; 95 % CI, 0.28395 – 0.73744; P = 0.001) Cox hazard analysis found that risk of RBO was significantly lower in 12-mm CSEEMS than in 10-mm FCSEMS. There were no significant differences between the 12-mm-CSEEMS group and 10-mm-FCSEMS group regarding the cause of RBO and adverse events.

Conclusions The 12-mm CSEEMS showed a low risk of RBO compared with 10-mm FCSEMS and was considered to be effective and safe for draining unresectable malignant distal biliary obstruction.