CC BY-NC-ND 4.0 · Rev Bras Ortop (Sao Paulo) 2019; 54(05): 579-586
DOI: 10.1016/j.rbo.2017.12.020
Artigo Original | Original Article
Sociedade Brasileira de Ortopedia e Traumatologia. Published by Thieme Revnter Publicações Ltda Rio de Janeiro, Brazil

Estudo comparativo entre artrotomografia computadorizada multi-slice e artroscopia na avaliação das lesões do manguito rotador[*]

Article in several languages: português | English
1   Serviço de Cirurgia de Ombro e Cotovelo, Hospital Português da Bahia, Salvador, BA, Brasil
,
Nicolas Gerardo Gómez-Cordero
2   Serviço de Ortopedia, Hospital Português da Bahia, Salvador, BA, Brasil
,
Paulo Mauricio Almeida Geambastiani
3   Curso Superior de Tecnologia em Radiologia, Instituto Federal de Educação, Ciência e Tecnologia da Bahia (IFBA), Salvador, BA, Brasil
,
Marcos Almeida Matos
4   Escola Bahiana de Medicina e Saúde Pública (EBMSP), Salvador, BA, Brasil
› Author Affiliations
Further Information

Publication History

16 October 2017

14 December 2017

Publication Date:
29 October 2019 (online)

Resumo

Objetivo Comparar os achados por imagem das alterações anatômicas da artrotomografia computadorizada multi-slice na avaliação das lesões do manguito rotador do ombro e correlacioná-los com os achados da artroscopia (exame diagnóstico padrão-ouro).

Materiais e Métodos Estudo longitudinal, prospectivo, comparativo de acurácia diagnóstica, feito de junho de 2016 a junho de 2017, em pacientes de ambos os sexos, com idades entre 40 e 70 anos, com lesão dos tendões do manguito rotador do ombro, e que tinham necessidade terapêutica de fazer artroscopia do ombro. Foram incluídos pacientes com contraindicação à realização de ressonância magnética. Após a artrotomografia computadorizada multi-slice, todos os pacientes foram submetidos a artroscopia.

Resultados Para a obtenção dos resultados, os seguintes parâmetros foram considerados: sensibilidade, especificidade, acurácia, valor preditivo positivo, valor preditivo negativo, coeficiente Kappa, e contraposição do método de imagem com a artroscopia.

Conclusão Na impossibilidade da realização da ressonância magnética (exame de imagem padrão-ouro), a artrotomografia computadorizada multi-slice se mostra um exame de imagem capaz de avaliar/diagnosticar as lesões do manguito rotador.

* Trabalho desenvolvido no Hospital Português da Bahia, Salvador, BA, Brasil. Publicado Originalmente por Elsevier Ltda.


 
  • Referências

  • 1 Ellman H, Kay SP. Arthroscopic subacromial decompression for chronic impingement. Two- to five-year results. J Bone Joint Surg Br 1991; 73 (03) 395-398
  • 2 Veado MAC, Fonseca RMF. O ombro do nadador veterano. Rev Bras Ortop 1992; 27: 686-690
  • 3 Farin PU, Kaukanen E, Jaroma H, Väätäinen U, Miettinen H, Soimakallio S. Site and size of rotator-cuff tear. Findings at ultrasound, double-contrast arthrography, and computed tomography arthrography with surgical correlation. Invest Radiol 1996; 31 (07) 387-394
  • 4 Waldt S, Bruegel M, Mueller D. , et al. Rotator cuff tears: assessment with MR arthrography in 275 patients with arthroscopic correlation. Eur Radiol 2007; 17 (02) 491-498
  • 5 Meislin RJ, Sperling JW, Stitik TP. Persistent shoulder pain: epidemiology, pathophysiology, and diagnosis. Am J Orthop 2005; 34 )12, Suppl) 5-9
  • 6 Andrade RP, Filho MRCC, Queiroz BC. Lesões do manguito rotador. Rev Bras Ortop 2004; 39 (11/12): 621-636
  • 7 Bedi A, Dines J, Warren RF, Dines DM. Massive tears of the rotator cuff. J Bone Joint Surg Am 2010; 92 (09) 1894-1908
  • 8 Matava MJ, Purcell DB, Rudzki JR. Partial-thickness rotator cuff tears. Am J Sports Med 2005; 33 (09) 1405-1417
  • 9 Lech O, Valenzuela Neto C, Severo A. Tratamento conservador das lesões parciais e completas do manguito rotador. Acta Ortop Bras 2000; 8 (03) 144-156
  • 10 McLaughlin HL. Rupture of the rotator cuff. J Bone Joint Surg Am 1962; 44: 979-983
  • 11 Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977; 33 (01) 159-174
  • 12 Guimarães MV. Avaliação do tratamento conservador do pinçamento subacromial e das lesões do manguito rotador. Rev Bras Ortop 1995; 30 (09) 645-648
  • 13 Almeida A, Valin MR, Zampieri R, Almeida NC, Roveda G, Agostini AP. Análise comparativa do resultado da sutura artroscópica da lesão do manguito rotador em pacientes fumantes e não fumantes. Rev Bras Ortop 2011; 46 (02) 172-175
  • 14 Checchia SL, Santos PD, Volpe Neto F, Cury RPL. Tratamento cirúrgico das lesões completas do manguito rotador. Rev Bras Ortop 1994; 29 (11/12): 827-836
  • 15 Tashjian RZ, Henn RF, Kang L, Green A. The effect of comorbidity on self-assessed function in patients with a chronic rotator cuff tear. J Bone Joint Surg Am 2004; 86 (02) 355-362
  • 16 Porcellini G, Paladini P, Campi F, Paganelli M. Shoulder instability and related rotator cuff tears: arthroscopic findings and treatment in patients aged 40 to 60 years. Arthroscopy 2006; 22 (03) 270-276
  • 17 Mileski RA, Snyder SJ. Superior labral lesions in the shoulder: pathoanatomy and surgical management. J Am Acad Orthop Surg 1998; 6 (02) 121-131
  • 18 Voos JE, Pearle AD, Mattern CJ, Cordasco FA, Allen AA, Warren RF. Outcomes of combined arthroscopic rotator cuff and labral repair. Am J Sports Med 2007; 35 (07) 1174-1179
  • 19 Shin SJ, Yoo JC, McGarry MH, Jun BJ, Lee TQ. Anterior capsulolabral lesions combined with supraspinatus tendon tears: biomechanical effects of the pathologic condition and repair in human cadaveric shoulders. Arthroscopy 2013; 29 (09) 1492-1497
  • 20 Boissonnault WG, Badke MB, Wooden MJ, Ekedahl S, Fly K. Patient outcome following rehabilitation for rotator cuff repair surgery: the impact of selected medical comorbidities. J Orthop Sports Phys Ther 2007; 37 (06) 312-319
  • 21 de Jesus JO, Parker L, Frangos AJ, Nazarian LN. Accuracy of MRI, MR arthrography, and ultrasound in the diagnosis of rotator cuff tears: a meta-analysis. AJR Am J Roentgenol 2009; 192 (06) 1701-1707
  • 22 Chung CB, Corrente L, Resnick D. MR arthrography of the shoulder. Magn Reson Imaging Clin N Am 2004; 12 (01) 25-38 , v–vi
  • 23 Gómez GFCA. Estudo comparativo entre artrotomografia computadorizada multislice e artrorressonância magnética na instabilidade do ombro correlacionadas com os achados artroscópicos. São Paulo: Departamento de Radiologia, Faculdade de Medicina da Universidade de São Paulo; 2008
  • 24 Farley TE, Neumann CH, Steinbach LS, Jahnke AJ, Petersen SS. Full-thickness tears of the rotator cuff of the shoulder: diagnosis with MR imaging. AJR Am J Roentgenol 1992; 158 (02) 347-351
  • 25 Rhee RB, Chan KK, Lieu JG, Kim BS, Steinbach LSMR. MR and CT arthrography of the shoulder. Semin Musculoskelet Radiol 2012; 16 (01) 3-14
  • 26 Fritz J, Fishman EK, Small KM. , et al. MDCT arthrography of the shoulder with datasets of isotropic resolution: indications, technique, and applications. AJR Am J Roentgenol 2012; 198 (03) 635-646
  • 27 De Filippo M, Bertellini A, Sverzellati N. , et al. Multidetector computed tomography arthrography of the shoulder: diagnostic accuracy and indications. Acta Radiol 2008; 49 (05) 540-549
  • 28 Charousset C, Bellaïche L, Duranthon LD, Grimberg J. Accuracy of CT arthrography in the assessment of tears of the rotator cuff. J Bone Joint Surg Br 2005; 87 (06) 824-828
  • 29 Rydberg J, Buckwalter KA, Caldemeyer KS. , et al. Multisection CT: scanning techniques and clinical applications. Radiographics 2000; 20 (06) 1787-1806
  • 30 Penrod B, Lane M, Hayda R, Tucker J, Prevost D, DeBerardino T. Multislice/multi-detector et for the evaluation of orthopaedic appliances: utility and optimization in a variety of clinical conditions. In: Society of Skeletal Radiology. Twenty-fourth Annual Meeting. 2001
  • 31 Farber JM, Buckwalter K. Multislice CT and the evaluation of osseous structures and joints in the presence of metal. In: Society of Skeletal Radiology. Twenty-fourth Annual Meeting. 2001
  • 32 Farber JM, Buckwalter KA. Sports-related injuries of the shoulder: instability. Radiol Clin North Am 2002; 40 (02) 235-249
  • 33 Owen RS, Iannotti JP, Kneeland JB, Dalinka MK, Deren JA, Oleaga L. Shoulder after surgery: MR imaging with surgical validation. Radiology 1993; 186 (02) 443-447
  • 34 Rand T, Trattnig S, Breitenseher M, Freilinger W, Cochole M, Imhof H. [MR arthrography of the shoulder joint in a postoperative patient sample]. Radiologe 1996; 36 (12) 966-970
  • 35 Magee TH, Gaenslen ES, Seitz R, Hinson GA, Wetzel LH. MR imaging of the shoulder after surgery. AJR Am J Roentgenol 1997; 168 (04) 925-928
  • 36 Gusmer PB, Potter HG, Donovan WD, O'Brien SJ. MR imaging of the shoulder after rotator cuff repair. AJR Am J Roentgenol 1997; 168 (02) 559-563
  • 37 Omoumi P, Bafort AC, Dubuc JE, Malghem J, Vande Berg BC, Lecouvet FE. Evaluation of rotator cuff tendon tears: comparison of multidetector CT arthrography and 1.5-T MR arthrography. Radiology 2012; 264 (03) 812-822
  • 38 Fritz J, Fishman EK, Fayad LM. MDCT Arthrography of the Shoulder. Semin Musculoskelet Radiol 2014; 18 (04) 343-351
  • 39 Oh JH, Kim JY, Choi JA, Kim WS. Effectiveness of multidetector computed tomography arthrography for the diagnosis of shoulder pathology: comparison with magnetic resonance imaging with arthroscopic correlation. J Shoulder Elbow Surg 2010; 19 (01) 14-20
  • 40 Mahmoud MK, Badran YM, Zaki HG, Ali AH. One-shot MR and MDCT arthrography of shoulder lesions with arthroscopic correlation. Egyptian J Radiol Nuclear Med. 2013; 44: 273-281