Abstract
Purpose: Assessment of Multi-Slice CT-colonography (MSCTC) with standard and low-dose technique
in comparison to conventional colonoscopy (CC). Materials and Methods: After standardized bowel cleansing, 28 men and 24 women (mean age 60,3 years) underwent
CC within two hours after MSCTC had been performed (4 × 2.5 mm collimation, 3 mm slice
width, 17.5 mm table feed, 120 kVp). In 19 patients, MSCTC was performed with 120
mAs (CTDIw, eff: 11.28 mGy), and in 33 patients with 10 mAs (CTDIw, eff: 0.94 mGy), respectively. After noise reduction using mathematical algorithms by
a dedicated software (ECCET), images were analyzed by two blinded readers in simultaneously
displayed 2D- and 3D-modes. Findings in MSCTC were compared to the results obtained
with CC. Results: Calculated effective doses ranged between 9 and 12 mSv for 120 mAs, and between 0.75
and 1 mSv for the low-dose technique. In standard dose MSCTC, 20 of 25 lesions (80
%) were found: all 7 tumors (100 %), one large polyp (> 10 mm; 100 %), 6 of 7 medium
sized polyps (9.9 to 5 mm; 86 %) and 6 of 10 small polyps (< 5 mm; 60 %). In low-dose
MSCTC, 32 of 44 lesions (73 %) were seen: all three large polyps (100 %), 13 of 14
medium sized polyps (93 %) and 16 of 27 small polyps (59 %). An overall sensitivity
of 78 % with a specificity of 68 % was calculated. False positive findings were seen
mostly for small lesions (12 for standard dose, 11 for low-dose). Conclusion: Despite a 12-fold reduction of radiation exposure, MSCTC in low-dose technique performs
comparably well to standard dose MSCTC. After mathematical noise reduction, more than
90 % of polyps larger than 5 mm can be detected.
Zusammenfassung
Ziel: Vergleich der Mehrschicht-CT-Kolographie (MSCTC) mit Standarddosis und in Niedrigdosis-Technik
mit der konventionellen Video-Endoskopie. Material und Methoden: Nach standardisierter Darmreinigung wurden 28 Männer und 24 Frauen (mittleres Alter:
60,3 Jahre) unmittelbar nach Durchführung einer MSCTC (Kollimation 4 × 2,5 mm, Schichtdicke
3 mm, Tischvorschub: 17,5 mm, 120 kV) endoskopiert. 19 Patienten wurden mit 120 mAs
(CTDIw, eff 11,28 mGy) und 33 Patienten mit 10 mAs (CTDIw, eff0,94 mGy) untersucht. Nach mathematischer Rauschunterdrückung wurden die Bilder auf
einer externen Workstation mit einer dedizierten Software (ECCET) im 2D- und 3D-Modus
durch zwei geblindete Untersucher im Konsensus bewertet. Die Ergebnisse wurden mit
den Befunden der Video-Endoskopie verglichen. Ergebnisse: Die berechnete effektive Dosis liegt bei 9 bis 12 mSv für eine Standard-MSCTC und
bei 0,75 - 1 mSv für die Niedrig-Dosis-Technik. Bei Standard-MSCTC wurden 20 von 25
Läsionen richtig detektiert (80 %): 7 Tumore (100 %), ein großer Polyp (> 10 mm, 100
%), 6 von 7 mittleren Polypen (9,9 - 5 mm; 86 %) und 6 von 10 kleinen Polypen (< 5
mm; 60 %). In Niedrig-Dosis-Technik wurden 32 von 44 Läsionen gesehen (73 %): drei
große Polypen (100 %), 13 von 14 mittleren Polypen (93 %) und 16 von 27 kleinen Polypen
(59 %). Falsch-positive Befunde wurden vornehmlich für kleine Polypen erhoben (12
bei Standard-MSCTC, 11 bei Niedrig-Dosis-Technik). Schlussfolgerung: Trotz einer 12fachen Dosisreduktion ist die Detektionsrate von Polypen bei der MSCTC
in Niedrig-Dosis-Technik vergleichbar der bei der MSCTC mit Standarddosis. Nach mathematischer
Rauschunterdrückung können mehr als 90 % der Polypen größer 5 mm detektiert werden.
Key words
Virtual CT-Colonography - Computed Tomography (CT), Radiation Exposure - Dose Reduction
- Colon, CT - Colon, neoplasms
Schlüsselwörter
Mehrschicht-Spiral-CT - Virtuelle CT-Kolographie - Dosisreduktion - Polypen - Kolon
Literatur
- 1
Fenlon H M, Nunes D P, Schroy P C , Barish M A, Clarke P D, Ferrucci J T.
A comparison of virtual and conventional colonoscopy for the detection of colorectal
polyps.
N Engl J Med.
1999;
341
1496-1503
- 2
Hara A K, Johnson C D, MacCarty R L, Welch T J, McCollough C H, Harmsen W S.
CT colonography: single- versus multi-detector row imaging.
Radiology.
2001;
219
461-465
- 3
Wessling J, Fischbach R, Domagk D, Lugering N, Neumann E, Heindel W.
Colorectal polyps: Detection with multi-slice CT colonography.
Fortschr Röntgenstr.
2001;
173
1069-1071
- 4
Ferrucci J T.
Colon cancer screening with virtual colonoscopy: promise, polyps, politics.
Am J Roentgenol.
2001;
177
975-988
- 5
Luboldt W, Debatin J F.
Virtual endoscopic colonography based on 3D MRI.
Abdom Imaging.
1998;
23
568-572
- 6
Luboldt W, Fletcher J G, Vogl T J.
Colonography: current status, research directions and challenges. Update 2002.
Eur Radiol.
2002;
12
502-524
- 7
Diederich S, Lenzen H, Windmann R, Puskas Z, Yelbuz T M, Henneken S, Klaiber T, Eameri M,
Roos N, Peters P E.
Pulmonary nodules: experimental and clinical studies at low-dose CT.
Radiology.
1999;
213
289-298
- 8
Aurich V, Winkler G, Hahn K, Martin A, Rodenacker K.
Noise Reduction in Images: some recent Edge-Preserving Methods.
Pattern Recognition and Image Analysis.
1999;
9
749-766
- 9
Johnson C D, Ahlquist D A.
Computed tomography colonography (virtual colonoscopy): a new method for colorectal
screening.
Gut.
1999;
44
301-305
- 10
Farrell R J, Morrin M M, McGee J B.
Virtual colonoscopy: a gastroenterologist's perspective.
Dig Dis.
1999;
17
185-193
- 11
Morrin M M, Farrell R J, Keogan M T, Kruskal J B, Yam C S, Raptopoulos V.
CT colonography: colonic distention improved by dual positioning but not intravenous
glucagon.
Eur Radiol.
2002;
12
525-530
- 12
Jurik A G, Jessen K A, Hansen J.
Image quality and dose in computed tomography.
Eur Radiol.
1997;
7
77-81
- 13
Takahashi M, Maguire W M, Ashtari M, Khan A, Papp Z, Alberico R, Campbell W, Eacobacci T,
Herman P G.
Low-dose spiral computed tomography of the thorax: comparison with the standard-dose
technique.
Invest Radiol.
1998;
33
68-73
- 14
Bensen S, Mott L A, Dain B, Rothstein R, Baron J.
The colonoscopic miss rate and true one-year recurrence of colorectal neoplastic polyps.
Polyp Prevention Study Group.
Am J Gastroenterol.
1999;
94
194-199
- 15
Schmiegel W, Adler G, Frühmorgen P, Frölsch U, Graeven U, Layer P, Petrasch S, Porschen R,
Pox C, Sauerbruch T, Schmoll H, Zeitz M.
Kolorektales Karzinom: Prävention und Früherkennung in der asymptomatischen Bevölkerung
- Vorsorge bei Risikopatienten - Endoskopische Diagnostik, Therapie und Nachsorge
von Polypen und Karzinomen.
Z Gastroenterol.
2000;
38
49-75
Dr. med. Mathias Cohnen
Institute of Diagnostic Radiology, MNR-Klinik
Moorenstrasse 5
40225 Duesseldorf
Telefon: + 49-221-8117752
Fax: + 49-221-8116145
eMail: cohnen@uni-duesseldorf.de