Open Access
CC BY-NC-ND 4.0 · J Neuroanaesth Crit Care 2022; 09(03): 162-167
DOI: 10.1055/s-0042-1750710
Original Article

Radiation Safety for Anesthesiologists and Other Personnel on Simultaneous PET/MRI: Possible Radiation Exposure from Patients While Performing Prolonged Duration Scans

Chandana Nagaraj
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Raman K. Joshi
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Dinesh Kumar
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Gopinath R.
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Dhritiman Chakrabarti
2   Department of Neuroanaesthesia and Neurocritical Care, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Pardeep K. Singh
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Sandhya Mangalore
1   Department of Neuro Imaging and Interventional Radiology, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
,
Ramesh Venkatapura
2   Department of Neuroanaesthesia and Neurocritical Care, National Institute of Mental Health and Neuro Sciences, Bengaluru, Karnataka, India
› Author Affiliations
Preview

Abstract

This observational study was conducted owing to the challenges of the positron emission tomography/magnetic resonance imaging (PET/MRI) that requires longer duration scanning of radiopharmaceutical injected patient and added MRI environment. The aim of this study was to assess radiation dose at different distances from the patient and the radiation burden to anesthesiologist and other personnel in performing PET/MRI under general anesthesia or sedation. First, the pre- and postscan whole body radiation exposure (WBE) from the patient were obtained for 45 minutes (n = 109) after injection of the radiopharmaceutical. The WBE was obtained at specific distances from brain (10, 30, and 100 cm) and abdomen (10 and 30cm) of patients undergoing F18 fluorodeoxyglucose PET/MRI brain or whole body studies. Second, WBE of the anesthesiologist and other staff working was separately measured using pocket dosimeters during the whole procedure. In brain scans, the mean absorbed dose rates (ADR) of prescan (45 minutes) and postscan (45 minutes) were 44.4 and 31.1 μSv at 10 cm, 14.9 and 9.7μSv at 30 cm, and 3.5 and 2.8 μSv at 100 cm, respectively, from surface of head. Similarly, it was 54.8 and 30.3 μSv at 10 cm, 23 and 13.6μSv at 30 cm, respectively, from surface of abdomen. In WB scans, the mean ADR was higher than the brain scans. Anesthesiologist exposure overall was found to be 4.84 µSv/patient/scan (112 patients). The anesthesiologist receives a safe mean effective dose in PET/MRI scanning. With good training and adequate planning, it is possible to decrease the radiation exposure to all the concerned personnel including anesthesiologists.



Publication History

Article published online:
20 January 2023

© 2022. Indian Society of Neuroanaesthesiology and Critical Care. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India