Applicability of colon capsule endoscopy as pan-endoscopy: From bowel preparation, transit, and rating times to completion rate and patient acceptance

Fanny E.R. Vuik
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, the Netherlands
,
Sarah Moen
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, the Netherlands
,
Stella A.V. Nieuwenburg
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, the Netherlands
,
Eline H. Schreuders
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, the Netherlands
,
Ernst J. Kuipers
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, the Netherlands
,
Manon C.W. Spaander
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, the Netherlands
› Author Affiliations
Preview

Abstract

Background and study aims Colon capsule endoscopy (CCE) has the potential to explore the entire gastrointestinal tract. The aim of this study was to assess the applicability of CCE as pan-endoscopy.

Patients and methods Healthy participants received CCE with bowel preparation (bisacodyl, polyethylene electrolyte glycol (PEG) + ascorbic acid) and booster regimen (metoclopramide, oral sulfate solution (OSS)). For each segment of the gastrointestinal tract, the following quality parameters were assessed: cleanliness, transit times, reading times, patient acceptance and safety of the procedure. When all gastrointestinal segments had cleansing score good or excellent, cleanliness of the whole gastrointestinal tract was assessed as good. Participants’ expected and perceived burden was assessed by questionnaires and participants were asked to grade the procedure (scale 0–10). All serious adverse events (SAEs) were documented.

Results A total of 451 CCE procedures were analyzed. A good cleansing score was achieved in the stomach in 69.6%, in the SB in 99.1 % and in the colon in 76.6 %. Cleanliness of the whole gastrointestinal tract was good in 52.8 % of the participants. CCE median transit time of the whole gastrointestinal tract was 583 minutes IQR 303–659). The capsule reached the descending colon in 94.7 %. Median reading time per procedure was 70 minutes (IQR 57–83). Participants graded the procedure with a 7.8. There were no procedure-related SAEs.

Conclusions CCE as pan-endoscopy has shown to be a safe procedure with good patient acceptance. When cleanliness of all gastrointestinal segments per patient, completion rate and reading time will be improved, CCE can be applied as a good non-invasive alternative to evaluate the gastrointestinal tract.

Supplementary material



Publication History

Received: 13 April 2021

Accepted: 02 July 2021

Article published online:
14 December 2021

© 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)