Int J Sports Med 2019; 40(08): 498-502
DOI: 10.1055/a-0875-4068
Training & STesting
© Georg Thieme Verlag KG Stuttgart · New York

Reliability of Trail Walking and Running Tasks Using the Stryd Power Meter

James Wilfred Navalta
1   Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, Las Vegas, United States
,
Jeffrey Montes
1   Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, Las Vegas, United States
,
Nathaniel G. Bodell
1   Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, Las Vegas, United States
2   Department of Kinesiology, California State University San Bernanino, San Bernadino, California, United States
,
Charli D. Aguilar
1   Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, Las Vegas, United States
,
Kara Radzak
1   Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, Las Vegas, United States
,
Jacob W. Manning
3   Kinesiology and Outdoor Recreation, Southern Utah University, Cedar City, United States
,
Mark DeBeliso
3   Kinesiology and Outdoor Recreation, Southern Utah University, Cedar City, United States
› Institutsangaben
Weitere Informationen

Publikationsverlauf



accepted 05. März 2019

Publikationsdatum:
09. Juli 2019 (online)

Preview

Abstract

Footpod monitors are wearable devices attaching to the shoe with the ability to sense oscillations in leg movement; however, few studies provide reliability. The purpose was to provide reliability data for outdoor tasks as measured by the Stryd Power Meter, which is a footpod monitor. Young healthy individuals (N=20, male n=12, female n=8) completed two 5-min self-paced walks along a trail, and two 5-min trail runs. Reliability of the tasks was determined using Coefficient of Variation (CV), Intraclass Correlation (ICC), and 95% confidence intervals (CI). Measures during trail running that returned a CV less than 10%, met the ICC threshold of 0.70, and displayed good to excellent 95% CI included pace, average elapsed power, average elapsed form power, average elapsed leg spring, and vertical oscillation. The only variable during walking to meet these criteria was maximal power (CV=4.02%, ICC=0.968, CI=0.902, 0.989). Running tasks completed on a trail generally return more consistent measures for variables that can be obtained from the Stryd footpod device than walking tasks.